← Back to Protocolssampling
Standard diatom cleaning and mounting protocol (Bacillariophyceae)
Local Knowledge Graph (7 entities)
Loading graph...
Description
Standard protocol for collecting freshwater diatoms from various substrates, cleaning with acids to remove organic matter, and mounting for microscopic examination. Includes both light microscopy and scanning electron microscopy preparation.
Typical Equipment
- tablespoon
- large-bore pipette with suction bulb
- Lugol's (IKI) solution
- sulfuric acid (H2SO4)
- potassium dichromate (K2Cr2O7)
- hydrogen peroxide (H2O2)
- Hyrax mounting medium
- microscope slides
- Leica DM LB2 research microscope
- Spot Insight Model 14.0 monochrome digital camera
- Hitachi S4700 Type II cold field emission SEM
- aluminum stubs
- Pelco Model 3 Sputter Coater
- gold
- palladium
- Spot Software version 4.5
Output Measurements
- valve morphology
- valve dimensions
- striae density
- taxonomic identification