← Back to Protocolsmeasurement

Stream Solute Workshop method

Subcategory: stream biogeochemistry
Standard reference: Stream Solute Workshop 1990, Mulholland et al. 2002
Papers: 2 | Mentions: 2

Local Knowledge Graph (22 entities)

Loading graph...

Description

Tracer Additions for Spiraling Curve Characterization method involving simultaneous injection of water tracer and nutrients with downstream breakthrough curve monitoring to quantify reach-scale nutrient uptake rates.

Typical Equipment

  • Rhodamine WT
  • NH4Cl
  • Na2HPO4
  • Databank handheld fluorometer
  • Turner Designs syringes
  • Gelman AE glass fiber filters
  • Turner Designs Trilogy Fluorometer Model #7200
  • Thermo Scientific GENESYS 10S UV-VIS Spectrophotometer

Output Measurements

  • nutrient uptake length
  • uptake velocity
  • areal uptake rate