← Back to DatasetsDataset

Total metals, sulfur and organic carbon data; Slate River floodplain, Crested Butte, CO; March 2021-October 2021

Creators: Pierce S, Engel M, Bargar J
Year: 2023
DOI: 10.15485/1875296
License: See source for details
Location: The Slate River (SR) a snow-dominated, headwater basin of the Upper Colorado River Basin (UCRB) located in the western United States. The SR is located just north of the town of Crested Butte, CO.
Temporal extent: 2021-03-28 to 2021-10-04
Bounding box: 38.909°N to 38.910°N, -107.029°W to -107.028°W
Publisher: RMBL
Tags: groundwater, floodplain, biogeochemical, organic carbon, SLAC, EARTH SCIENCE > TERRESTRIAL HYDROSPHERE > WATER QUALITY/WATER CHEMISTRY, EARTH SCIENCE > TERRESTRIAL HYDROSPHERE > GROUND WATER, EARTH SCIENCE > TERRESTRIAL HYDROSPHERE > GROUND WATER > GROUNDWATER CHEMISTRY, EARTH SCIENCE > TERRESTRIAL HYDROSPHERE > WATER QUALITY/WATER CHEMISTRY > WATER CHARACTERISTICS > WATER TRACE ELEMENTS, EARTH SCIENCE > TERRESTRIAL HYDROSPHERE > WATER QUALITY/WATER CHEMISTRY > CONTAMINANTS > METALS/MINERALS, EARTH SCIENCE > ATMOSPHERE > ATMOSPHERIC CHEMISTRY > SULFUR COMPOUNDS > SULFATE, carbon, CATEGORICAL:NONE EARTH SCIENCE > TERRESTRIAL HYDROSPHERE > WATER QUALITY/WATER CHEMISTRY > CONTAMINANTS > METALS/MINERALS, EARTH SCIENCE > TERRESTRIAL HYDROSPHERE > WATER QUALITY/WATER CHEMISTRY > CONTAMINANTS > ORGANIC MATTER, VARIABLE:GCMD EARTH SCIENCE > TERRESTRIAL HYDROSPHERE > WATER QUALITY/WATER CHEMISTRY >, Hydrology & Watersheds, Snow & Ice, Groundwater, Soil Science, Geochemistry & Isotopes, Field Methods & Monitoring, Gunnison Basin, Research Programs

Description

This data package includes processed and undiluted measurements for metal, sulfur and organic carbon concentrations from pore water (groundwater) samples from the Slate River floodplain of Crested Butte, CO, a focus field site for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? Samples were collected between March and October of 2021. These measurements were all recorded at the Environmental Measurements Facility (EM-1) at Stanford University in Stanford, CA. Groundwater samples were extracted from a network of installed rhizon (Rhizosphere Research Products, part no. 19.60.21F, 0.6 micrometer mesh size) and piezometer wells within the river floodplain. All water samples were shaded from sun exposure during extraction from the subsurface and preserved at 2C until measured at EM-1. Analysis by ICP-MS: Measurements for total metals were performed on an inductively coupled plasma optical emission spectrometer (ICP-OES; iCAP 6300, Thermo Scientific, Cambridge, U.K.). Calibration standards were prepared from the mulit element stock solution (Sigma-Aldrich Multielement standard for ICP, St. Louis, MO) using matrix matched to sample solutions (2% HNO3). Calibration curves included 5 points with correlation coefficients of >0.99. The QC protocol includes a continuing calibration blank and quality control samples that are analyzed just after calibration and again every 20 samples and at the completion of the run. Acceptable QC responses must be between 90-110% of the certified value. Analysis by Total Organic Carbon: Dissolved organic carbon concentrations were quantified on a total organic carbon (TOC) analyzer (TOC-L, Shimadzu, Kyoto, Japan) running the NPOC method. Standard curves were developed using an Organic Carbon Standard from RICCA Chemical Company (Arlington,TX). A series of 4 to 6 standards were automatically diluted by the instrument in a concentration range that spans that of the samples. A blank sample was run just after the calibration curve and at the end of the run. A QC sample was run every 25 samples. Acceptable QC responses must be between 90-110% of the certified value. All files are in csv format.

Local Knowledge Graph (6 entities)